Leading Electromagnetic Flow Meter Manufacturer
Gen Creative Engineers Limited is one of the leading Electromagnetic Flow Meter Manufacturer, Supplier & Exporter in India. Designed with precision engineering, our flow meters deliver highly accurate liquid flow measurement without obstruction, making them useful for industries such as water treatment, chemical processing, food & beverage, and pharmaceuticals. Built with durable, corrosion‑resistant materials and modern technology, these meters ensure long service life, easy installation, and energy-efficient operation.
Our Electromagnetic Water Flow Meter helps industries achieve consistent results, reduce operational costs, and maintain compliance with global standards. With a strong focus on innovation and reliability, Creative Engineers provides solutions that enhance efficiency and performance across diverse applications.
Electromagnetic Flow Meter Applications:
- Water Supply Networks, Chemical, Petrochemical and Process Industries (Only Conductive Liquids)
- Pharmaceutical Industries / Paper and pulp Industries / Fertiliser Industries / Beverage Industries
- Waste - Water management, Sugar, Food, drug, and beverage industries
- Effluent Treatment Plants, Aluminum, Steel, Mining and Dredging Industries
Electromagnetic Flow Meter Specifications:
- Suitable for pipe sizes: DN 10 to DN 2000
- Media Conductivity (Min): 10 μs/cm (Consult factory for 5 μs/cm)
- Media Pressure: PN 40 up to DN 80, PN 16 up to DN 200 & PN 10 up to DN 600
- Media Temperature (PTFE): 0"-180°C with remote transmitter
- 0"-120°C with integral transmitter
- 0"-90°C max for other Liners
- Material: SS 316 (Non-Magnetic)
- Liner: PTFE / Neoprene / Polyurethane
- Electrode: SS / Hostelloy C / Ta / Ti / PL
- End Connection / Flanges: Carbon steel / SS 304 / SS 316 / SS 316L
- Coil Housing: Carbon steel / SS, Epoxy painted
- Transmitter: Cast aluminum (Lm6), Epoxy painted
- Power supply: 110 / 240 V AC + 15 % 50 Hz
- Power consumption: 20 VA
- Analog Output: 4-20 mA / DC / 0-20 mA DC
- Communication port (Optional): RS-23 / RS-485 MODBUS RTU protocol
- Response time: 5 seconds
- Flow velocity Range: 0.3 to 10 m/s
- Ingress Protection: IP-65 (IP-68 on request)
- LED Display: 4-digit indication for flow rate and 8-digit indication for Totaliser programming from keyboard for engineering unit
- Accuracy: 0.5 % of the measured value (calibrated) at reference conditions
- Accuracy: 2% of span
- For flow between 0 and 100%: Refer to the error diagram.
- Reference Conditions
- Power Supply: Nominal
- Ambient Temperature: 25 ± 2°C
- Load Resistance: 500
- Repeatability: + 0.2% of span
- Effect of Ambient Temperature: Less than 0.2% per 10°C
- Effect of power supply: Less than 0.1% per
- 10% Voltage Variation
- Effect of Load Resistance Less than 0.1% of span