Are you looking for an electromagnetic flow meter manufacturer, supplier, and exporter in Ahmedabad, India? Creative Engineers is your top choice. We specialize in manufacturing high-quality electromagnetic flow meters engineered for precise and efficient measurements across diverse industries. Our cutting-edge technology guarantees exceptional accuracy, durability, and minimal maintenance, making us a trusted name in the industry. Ideal for water, wastewater, and various industrial applications, our solutions are designed to excel in any environment.

Electromagnetic Flow Meter Applications:

  1. Water Supply Networks, Chemical, Petrochemical and Process Industries (Only Conductive Liquids)
  2. Pharmaceutical Industries / Paper and pulp Industries / Fertilizer Industries / Beverage Industries
  3. Waste - Water management , Sugar, Food, Drug and Beverages Industries
  4. Effluent Treatment Plants, Aluminum, Steel, Mining and Dredging Industries

Electromagnetic Flow Meter Specifications:

  1. Suitable for pipe sizes : DN 10 to DN 2000
  2. Media Conductivity (Min) : 10 us / cm (Consult factory for 5 us/cm)
  3. Media Pressure: PN 40 up to DN 80, PN 16 upto DN 200 & PN 10 up to DN 600
  4. Media Temperature (PTFE) : 0"-180c with remote transmitter
  5. 0"-120c with integral transmitter
  6. 0"-90c max for other Liners
  7. Material : SS 316 (Non - Magnetic)
  8. Liner : PTFE / Neoprene / Polyurethane
  9. Electrode : SS / Hostelloy C / Ta / Ti / PL
  10. End Connection / Flanges : Carbon steel / SS 304 / SS 316 / SS 316L
  11. Coil Housing : Carbon steel / SS, Epoxy painted
  12. Transmitter : Cast aluminum (Lm6), Epoxy painted
  13. Power supply : 110 / 240 V AC + 15 % 50 Hz
  14. Power consumption : 20 VA
  15. Analog Output : 4-20 mA / DC / 0-20 mA DC
  16. Communication port (Optional) : RS -23 / RS - 485 MODBUS RTU protocol
  17. Response time : 5 second
  18. Flow velocity Range : 0.3 to 10 m/s
  19. Ingresss Protection : IP - 65 (IP 68 on request)
  20. LED Display : 4 Digit Indication for flow rate and 8 digit indication for Totaliser programming from keyboard for engineering unit
  21. Accuracy : 0.5 % of measured value (calibrated) at eference conditions
  22. Accuracy : 2 % of span
  23. For flow Between 0 to 100 % : Refer Error Diagram
  24. Reference Conditions
  25. Power Supply : Nominal
  26. Ambient Temperature : 25 + 2c
  27. Load Resistance : 500
  28. Repeatability : + 0.2% of span
  29. Effect of Ambient Temperature : Less then 0.2% per 10c
  30. Effect of power supply : Less then 0.1% per
  31. 10% Voltage Variation
  32. Effect of Load Resistance Less than 0.1% of span